RF test equipment
Coaxial Connector (RF) Contacts can be evaluated for rf test equipment. Match impedance, mating interface, frequency range and termination to the equipment interface.
Explore products in this family. Open a product for details, or send us your drawing for a custom build.
| Part number | Description |
|---|---|
| 413657-8 | CONN PIN CONTACT BNC CRIMP GOLD |
| GT13-30/1.6-2.9SCF(70) | CONN SOCKET CONTACT F CRIMP TIN |
| R280469000 | ACCESSORY / REMOVABLE FEMALE CEN |
| SPC8S-221 | SIZE 8 TWINAX SCKT JACK |
| DK-602-0157-2 | CONN SOCKET CONTACT SOLDER |
| 3221-40071 | SMPM FEMALE VITA 67.3 CONTACT |
| 8001-4107 | CONN PIN CONTACT GOLD |
| GT16G-2428SCF | CONN SOCKET INNER CONTACT F CRMP |
| 1-331352-2 | CONN PIN CONTACT BNC CRIMP GOLD |
| GT13-2428/F4-5SCF(55) | CONN SOCKET CONTACT F CRIMP TIN |
| 2332772-1 | NANORF PIN CONTACT, BACKPLANE 08 |
| SF9421-6000 | CONN PIN CONTACT BMA GOLD |
| 3821-40023 | SMPS VITA 67.3 BACKPLANE CONTACT |
| 3221-40066 | SMPM FEMALE VITA 67.3 CONTACT |
| SF9421-6001 | CONN PIN CONTACT BMA GOLD |
| 226853-3 | CONN SOCKET CONTACT MINI UHF TIN |
| GT16-30PCF | CONN PLUG CENTER TERMINAL CRIMP |
| SF3811-60059 | VITA 67.3 SMPS PLUG-IN CONTACT F |
| FKCP03402 | FAKRA, MALE CONTACT, RG-58 |
| 2203270-4 | CENTER CONTACT, IN-LINE FEMALE, |
| GT21-30/1.1-2.2SCF | CONN TERMINAL CRIMP |
| FKCP03302 | FEMALE FAKRA CONTACT , RG-58 |
| GT15B-2024SCF(70) | CONN HID LAMP TERMINAL |
| FKCP08402 | FEMALE FAKRA CONTACT |
The Coaxial Connector (RF) Contacts range covers coaxial connections for radio-frequency signal paths.
Compare impedance, mating interface, frequency range and termination for the required installation. These are separate conductive contacts. Match the contact to its housing, wire range and specified termination tooling.
Review Wire Gauge, Contact Termination, Pin or Socket, Type and Mounting Type on the individual product page before choosing a part.
Potential uses vary by part number. Check the listed specifications and equipment requirements before selecting a product.
Coaxial Connector (RF) Contacts can be evaluated for rf test equipment. Match impedance, mating interface, frequency range and termination to the equipment interface.
For antenna interfaces, verify Wire Gauge, Contact Termination, Pin or Socket, Type and Mounting Type on the selected Coaxial Connector (RF) Contacts. These are separate conductive contacts. Match the contact to its housing, wire range and specified termination tooling.
In communications modules, allow for the required mounting, routing or termination space. Check impedance, mating interface, frequency range and termination before assembly.
For coaxial connector (rf) contacts inspection, identify the original Coaxial Connector (RF) Contacts part number and mating arrangement. Compare Wire Gauge, Contact Termination, Pin or Socket, Type and Mounting Type before substitution.
Compare the interfaces, construction and selection details of these two product options.
Example: GT5-30/F4-5PCF(70)
Example: GT13-2428/1.6-2.5SCF(70)
The comparison describes common construction differences; final suitability depends on your electrical, mechanical and lifetime requirements.
Practical answers to help you prepare your drawing and specifications.
This category covers coaxial connections for radio-frequency signal paths. These are separate conductive contacts. Match the contact to its housing, wire range and specified termination tooling.
Examples in this category include 30 AWG, 24-28 AWG and 20-22 AWG. Match the selected Coaxial Connector (RF) Contacts to the required impedance, mating interface, frequency range and termination.
For Coaxial Connector (RF) Contacts, check Wire Gauge, Contact Termination, Pin or Socket, Type and Mounting Type against the equipment or mating-part drawing. Confirm the installed clearance and termination access as well as the nominal interface size.
Check impedance, mating interface, frequency range and termination for the selected part. Use its stated operating conditions and complete assembly requirements; appearance alone does not establish the electrical or environmental rating.
These are separate conductive contacts. Match the contact to its housing, wire range and specified termination tooling. For Coaxial Connector (RF) Contacts, identify the matching system and required assembly parts before ordering.
GT5-30/F4-5PCF(70) specifies Wire Gauge: 30 AWG and Contact Termination: Crimp. GT13-2428/1.6-2.5SCF(70) specifies Wire Gauge: 24-28 AWG and Contact Termination: Crimp. Check the full mating and installation requirements before treating different Coaxial Connector (RF) Contacts as replacements.
Send the manufacturer and full part number, quantity and required delivery destination. For this category, include impedance, mating interface, frequency range and termination and a mating or installation drawing when a replacement is needed.
Send a drawing, a BOM, a part number or just one sentence. Our engineers review every enquiry and reply within 24 hours.
We use cookies to collect information about how you use this site. We use this information to make the website work as well as possible and improve our services.more details