icon ISO 9001 · ISO 13485 · IATF 16949 · ISO 14001 certified manufacturer

Products

Explore products in this family. Open a product for details, or send us your drawing for a custom build.

Part number Description
MDM-21PHC10F

MICRO 21C P 30" WHT FLOAT

MDM-21PH045F

MICRO 21C P 24" WHT FLOAT

M7PPK-3710J

D-SUB CABLE MMM37K/MC37G/MMM37K

MDM-21PH046F

MICRO 21C P 72" RBW FLOAT

A7SSB-3706G

CABLE D-SUB-AFM37B/AE37G/AFM37B

MDM-21PH042L

MICRO 21C P 120" YEL JACKS

A7OOB-2510M

CABLE D-SUB-AFN25B/AE25M/AFN25B

A7FFB-3706M

CABLE D-SUB-AFP37B/AE37M/AFP37B

MDM-21PH042F

MICRO 21C P 120" YEL FLOAT

HDB-44AFFM-SL7A01

CABLE ASSY HD44 SHLD BLACK 1M

C7PSG-3710M

DSUB CABLE - CMM37G/AE37M/CFM37G

A7OOB-1506G

CABLE D-SUB-AFN15B/AE15G/AFN15B

DCDA9S6E5-18.0B

DC PLSTC 9 POS SKT 18" WIRE

DCDA9P6E5-18.0B

DC PLSTC 9 POS PLG 18" WIRE

628-000-969

CABLE ASSEMBLY

M7VWK-3710J

D-SUB CABLE MMU37K/MC37G/MFU37K

A7PSB-3706G

CABLE D-SUB-AMM37B/AE37G/AFM37B

A7MFB-3710G

CABLE D-SUB-AMP37B/AE37G/AFP37B

A7VWB-2506M

CABLE D-SUB-AMU25B/AE25M/AFU25B

MDM-21SH013L

MICRO 21C S 48" YEL JACKS

A7OOB-1506M

CABLE D-SUB-AFN15B/AE15M/AFN15B

M7SSK-2510R

D-SUB CABLE MFM25K/MC26M/MFM25K

SDB-09AFFM-SL7A10

CABLE ASSY DB09 SHLDED BLACK 10M

DCDA9P6E5-36.0B

DC PLSTC 9 POS PLG 36" WIRE

About D-Sub Cables

D-Sub Cable Assemblies includes D-sub interconnects with different contact counts and end configurations.

When selecting an assembly, check contact count, gender, pinout, mounting hardware and cable shielding.

Straight-through, crossover and equipment-specific D-sub cables may use similar shells. Confirm the pin-to-pin map instead of inferring it from the connector size.

D-Sub Cables

Typical Applications

Potential uses vary by part number. Check the listed specifications and equipment requirements before selecting a product.

Serial controller links

Serial controller links

Confirm the serial standard and pinout; a D-sub shell does not identify the electrical interface.

Instrument rear-panel wiring

Instrument rear-panel wiring

Check contact count, gender and screw-lock hardware against the instrument drawing.

Legacy workstation servicing

Legacy workstation servicing

Distinguish straight-through, crossover and equipment-specific wiring before replacement.

Panel extension routing

Panel extension routing

Match both ends and allow clearance for the backshell, mounting screws and cable bend.

Male D-sub termination vs. Female D-sub termination

Compare the interfaces, construction and selection details of these two product options.

Male D-sub termination

Representative listed part: 1200980207.

  • 1st Connector Plug, Male Pins
  • 2nd Connector Plug, Male Pins (2), Right Angle
  • Type DB9
  • Number of Positions 9
  • Shielding Shielded
  • Length 3.28' (1.00m)

Female D-sub termination

Representative listed part: M7OOK-0906J.

  • 1st Connector Receptacle, Female Sockets
  • 2nd Connector Receptacle, Female Sockets
  • Type DB9
  • Number of Positions 9
  • Shielding Unshielded
  • Length 6.00' (1.83m)

The comparison describes common construction differences; final suitability depends on your electrical, mechanical and lifetime requirements.

Frequently Asked Questions

Practical answers to help you prepare your drawing and specifications.

Are D-sub cables with the same pin count wired identically?

Check both mating ends and obtain the pin-to-pin wiring required by the equipment. Position count identifies only part of the connection; it does not document straight-through wiring, crossovers or unused contacts.

Read the contact description at both ends and compare it with the equipment connector. Specify the shell size, position count and retention arrangement as well as male pins or female sockets.

Confirm the lead identification, length and termination requirements for the installation. A connector-to-leads assembly requires a defined wiring plan rather than the same mating arrangement as a fully terminated cable.

Straight-through, crossover and equipment-specific D-sub cables may use similar shells. Confirm the pin-to-pin map instead of inferring it from the connector size.

1200980207 is shown as male d-sub termination, with 1st Connector listed as Plug, Male Pins. M7OOK-0906J is shown as female d-sub termination, with 1st Connector listed as Receptacle, Female Sockets. These are two examples, not a statement that every part has either specification.

Provide the original manufacturer and complete part number, or a drawing. For this range, compare contact count, gender, pinout, mounting hardware and cable shielding. Identify any requirement not covered by the listing rather than selecting only by length or appearance.

Supply a mating-interface drawing and the required contact count, gender, pinout, mounting hardware and cable shielding. Add quantity, destination and any inspection requirements. Changes must be reviewed for the selected construction before compatibility, pricing or delivery can be confirmed.

Tell us what you need to build

Send a drawing, a BOM, a part number or just one sentence. Our engineers review every enquiry and reply within 24 hours.

  • Engineering review within 24 hours
  • NDA available before drawings are shared
  • Free samples in 5-7 days after drawing approval
Inquiry Drawer

Review & Submit Request