icon ISO 9001 · ISO 13485 · IATF 16949 · ISO 14001 certified manufacturer

Products

Explore products in this family. Open a product for details, or send us your drawing for a custom build.

Part number Description
AK579-3

CABLE ASSY HPDB50 SHLD BEIGE 3M

AK441/F-.9

CABLE ASSY DB25-HPDB68 899.16MM

MDM-24C4SHW01B-A174

MICRO

A7PPG-0906M

DSUB CABL-AMM09G/ AE10M / AMM09G

MDM-24C4PH041B

MICRO

MDM-100SH048M15-A174

MICRO

MDM-24C4SH004B

MICRO

A7PSG-3710G

DSUB CABL-AMM37G/ AE37G / AFM37G

A7FFG-2510G

DSUB CABL-AFP25G/ AE25G / AFP25G

A7MMG-0906G

DSUB CABL-AMP09G/ AE10G / AMP09G

710-10091-00500

CABLE ASSY DB25 SHLD BEIGE 5M

A7PXG-3710M

DSUB CABL-AMM37G/ AE37M / X

A7SXG-1506M

DSUB CABL-AFM15G/ AE15M / X

700-10117-00180

CABLE ASSY DB25 SHLD BEIGE 1.8M

177-710-1-37CS4K1-14MAN

MICRO-D SUBMINIATURE

MDM-25SH010P

MICRO 25C S 30" YEL JACKP

710-10033-00300

CABLE ASSY DB25 SHLD BEIGE 3M

710-10016-00500

CABLE ASSY DB25 SHLD BEIGE 5M

MDM-25SHC20K-A174

MICRO 25C S 3" WHT JACKS NI

MDM-25SL2K

MICRO 25C S 1" CU JACKS

MDM-51SH003P-A141

MDM-51SH003P-A141

MDM-51SH034K

CABLE ASY D TO WIRE 51P 203.2MM

MDM-15PH006G7

MICRO 15 M 36" RBW W/LS HDW

MDM-15PH047L-A174

MICRO 15C P 6" WHT JACKS NI

About D-Sub Cables

D-Sub Cable Assemblies includes D-sub interconnects with different contact counts and end configurations.

When selecting an assembly, check contact count, gender, pinout, mounting hardware and cable shielding.

Straight-through, crossover and equipment-specific D-sub cables may use similar shells. Confirm the pin-to-pin map instead of inferring it from the connector size.

D-Sub Cables

Typical Applications

Potential uses vary by part number. Check the listed specifications and equipment requirements before selecting a product.

Serial controller links

Serial controller links

Confirm the serial standard and pinout; a D-sub shell does not identify the electrical interface.

Instrument rear-panel wiring

Instrument rear-panel wiring

Check contact count, gender and screw-lock hardware against the instrument drawing.

Legacy workstation servicing

Legacy workstation servicing

Distinguish straight-through, crossover and equipment-specific wiring before replacement.

Panel extension routing

Panel extension routing

Match both ends and allow clearance for the backshell, mounting screws and cable bend.

Male D-sub termination vs. Female D-sub termination

Compare the interfaces, construction and selection details of these two product options.

Male D-sub termination

Representative listed part: 1200980207.

  • 1st Connector Plug, Male Pins
  • 2nd Connector Plug, Male Pins (2), Right Angle
  • Type DB9
  • Number of Positions 9
  • Shielding Shielded
  • Length 3.28' (1.00m)

Female D-sub termination

Representative listed part: M7OOK-0906J.

  • 1st Connector Receptacle, Female Sockets
  • 2nd Connector Receptacle, Female Sockets
  • Type DB9
  • Number of Positions 9
  • Shielding Unshielded
  • Length 6.00' (1.83m)

The comparison describes common construction differences; final suitability depends on your electrical, mechanical and lifetime requirements.

Frequently Asked Questions

Practical answers to help you prepare your drawing and specifications.

Are D-sub cables with the same pin count wired identically?

Check both mating ends and obtain the pin-to-pin wiring required by the equipment. Position count identifies only part of the connection; it does not document straight-through wiring, crossovers or unused contacts.

Read the contact description at both ends and compare it with the equipment connector. Specify the shell size, position count and retention arrangement as well as male pins or female sockets.

Confirm the lead identification, length and termination requirements for the installation. A connector-to-leads assembly requires a defined wiring plan rather than the same mating arrangement as a fully terminated cable.

Straight-through, crossover and equipment-specific D-sub cables may use similar shells. Confirm the pin-to-pin map instead of inferring it from the connector size.

1200980207 is shown as male d-sub termination, with 1st Connector listed as Plug, Male Pins. M7OOK-0906J is shown as female d-sub termination, with 1st Connector listed as Receptacle, Female Sockets. These are two examples, not a statement that every part has either specification.

Provide the original manufacturer and complete part number, or a drawing. For this range, compare contact count, gender, pinout, mounting hardware and cable shielding. Identify any requirement not covered by the listing rather than selecting only by length or appearance.

Supply a mating-interface drawing and the required contact count, gender, pinout, mounting hardware and cable shielding. Add quantity, destination and any inspection requirements. Changes must be reviewed for the selected construction before compatibility, pricing or delivery can be confirmed.

Tell us what you need to build

Send a drawing, a BOM, a part number or just one sentence. Our engineers review every enquiry and reply within 24 hours.

  • Engineering review within 24 hours
  • NDA available before drawings are shared
  • Free samples in 5-7 days after drawing approval
Inquiry Drawer

Review & Submit Request

This site uses cookies

We use cookies to collect information about how you use this site. We use this information to make the website work as well as possible and improve our services.more details