icon ISO 9001 · ISO 13485 · IATF 16949 · ISO 14001 certified manufacturer

Products

Explore products in this family. Open a product for details, or send us your drawing for a custom build.

Part number Description
192568-02

CABLE ASSY DB25 BLACK 2M

782316-04

CABLE ASSY DB37 BLACK 4M

778621-02

CABLE ASSY DB37 BLACK 2M

PCL-10250-2E

CABLE ASSY DB50 TO DB100 BLK 2M

PCL-10268-2E

CABLE ASSY HPCN100-HPDB68 BLK 2M

PCL-10137-2E

CABLE ASSY DB37 SHLD 2M

PCL-10137H-1E

CABLE ASSY DB37 SHLD 1M

PCL-10168H-1E

CABLE ASSY HPDB68 SHLD 1M

PCL-10250-1E

CABLE ASSY DB50 TO DB100 BLK 1M

5-1532137-8

CABLE ASSY

834219222

CABLE ASSY CMD 9 SCKT TO 9 SKT

1-1532197-8

CABLE ASSY

EMVG0025

CABLE ASSY DB15 BLACK 7.62M

M02-116A

CABLE ASSY DB09 DB25 GRY 3.05M

M05-103

CABLE ASSY DB09 SHLD GRAY 3.05M

M05-105

CABLE ASSY DB09 SHLD GRAY 1.83M

M02-250

CABLE ASSY DB25 SHLD GRAY 15.24M

M02-1156N

CABLE ASSY DB09 DB25 GRY 1.83M

M02-116

CABLE ASSY DB09 DB25 BLK 1.83M

M01-017

CABLE ASSY DB25 SHLD GRAY 3.05M

M02-114

CABLE ASSY DB09-DB25 GRY 304.8MM

M02-255

CABLE ASSY DB25 SHLD GRAY 15.24M

A02-112

CABLE ASSY DB25 SHLD GRAY 7.62M

A02-101

CABLE ASSY DB25 SHLD GRAY 1.83M

About D-Sub Cables

D-Sub Cable Assemblies includes D-sub interconnects with different contact counts and end configurations.

When selecting an assembly, check contact count, gender, pinout, mounting hardware and cable shielding.

Straight-through, crossover and equipment-specific D-sub cables may use similar shells. Confirm the pin-to-pin map instead of inferring it from the connector size.

D-Sub Cables

Typical Applications

Potential uses vary by part number. Check the listed specifications and equipment requirements before selecting a product.

Serial controller links

Serial controller links

Confirm the serial standard and pinout; a D-sub shell does not identify the electrical interface.

Instrument rear-panel wiring

Instrument rear-panel wiring

Check contact count, gender and screw-lock hardware against the instrument drawing.

Legacy workstation servicing

Legacy workstation servicing

Distinguish straight-through, crossover and equipment-specific wiring before replacement.

Panel extension routing

Panel extension routing

Match both ends and allow clearance for the backshell, mounting screws and cable bend.

Male D-sub termination vs. Female D-sub termination

Compare the interfaces, construction and selection details of these two product options.

Male D-sub termination

Representative listed part: 1200980207.

  • 1st Connector Plug, Male Pins
  • 2nd Connector Plug, Male Pins (2), Right Angle
  • Type DB9
  • Number of Positions 9
  • Shielding Shielded
  • Length 3.28' (1.00m)

Female D-sub termination

Representative listed part: M7OOK-0906J.

  • 1st Connector Receptacle, Female Sockets
  • 2nd Connector Receptacle, Female Sockets
  • Type DB9
  • Number of Positions 9
  • Shielding Unshielded
  • Length 6.00' (1.83m)

The comparison describes common construction differences; final suitability depends on your electrical, mechanical and lifetime requirements.

Frequently Asked Questions

Practical answers to help you prepare your drawing and specifications.

Are D-sub cables with the same pin count wired identically?

Check both mating ends and obtain the pin-to-pin wiring required by the equipment. Position count identifies only part of the connection; it does not document straight-through wiring, crossovers or unused contacts.

Read the contact description at both ends and compare it with the equipment connector. Specify the shell size, position count and retention arrangement as well as male pins or female sockets.

Confirm the lead identification, length and termination requirements for the installation. A connector-to-leads assembly requires a defined wiring plan rather than the same mating arrangement as a fully terminated cable.

Straight-through, crossover and equipment-specific D-sub cables may use similar shells. Confirm the pin-to-pin map instead of inferring it from the connector size.

1200980207 is shown as male d-sub termination, with 1st Connector listed as Plug, Male Pins. M7OOK-0906J is shown as female d-sub termination, with 1st Connector listed as Receptacle, Female Sockets. These are two examples, not a statement that every part has either specification.

Provide the original manufacturer and complete part number, or a drawing. For this range, compare contact count, gender, pinout, mounting hardware and cable shielding. Identify any requirement not covered by the listing rather than selecting only by length or appearance.

Supply a mating-interface drawing and the required contact count, gender, pinout, mounting hardware and cable shielding. Add quantity, destination and any inspection requirements. Changes must be reviewed for the selected construction before compatibility, pricing or delivery can be confirmed.

Tell us what you need to build

Send a drawing, a BOM, a part number or just one sentence. Our engineers review every enquiry and reply within 24 hours.

  • Engineering review within 24 hours
  • NDA available before drawings are shared
  • Free samples in 5-7 days after drawing approval
Inquiry Drawer

Review & Submit Request

This site uses cookies

We use cookies to collect information about how you use this site. We use this information to make the website work as well as possible and improve our services.more details