icon ISO 9001 · ISO 13485 · IATF 16949 · ISO 14001 certified manufacturer

Products

Explore products in this family. Open a product for details, or send us your drawing for a custom build.

Part number Description
R-SS-075MSR

30IN SATA III DEVICE CABLE STRAI

SS-02MSR

8" SATA III DEVICE CABLE STRAIGH

30SR330YL

13" SATA CABLE STRAIGHT TO RIGHT

SFP-H10GB-CU2M-HW-C

CABLE SFP+ TO SFP+ M-M 2M

R-SS-05MRR

20IN SATA DEVICE CABLE RIGHT TO

30SR330BL

13" SATA CABLE STRAIGHT TO RIGHT

SS-05MSS

20" INTERNAL SATA CABLE STRAIGHT

SS-02MRR

8" SATA DEVICE CABLE RIGHT TO RI

SS-035SS

14 INCH SATA II DEVICE CABLE STR

30SS991YL

39" YELLOW LATCHING SATA III STR

SS-05MSR

20" SATA III DEVICE CABLE STRAIG

SS-01MSR

4" SATA III DEVICE CABLE STRAIGH

30SR584YN

23IN SATA III 6GB/S LOW PROFILE

SS-01MRR

4" SATA DEVICE CABLE RIGHT TO RI

SS-01MSL

4" BLACK SATA DEVICE CABLE STRAI

R-SS-01MRL

4IN SATA DEVICE CABLE RIGHT TO L

R-SS-02MRR

8IN SATA DEVICE CABLE RIGHT TO R

30SR991YN

39IN SATA III 3GB/S LOW PROFILE

30SR584YL

23" SATA CABLE STRAIGHT TO RIGHT

QSSFP-P03M0-2

CABLE 4SFP+-QSFP+ M-M 3M

701-002

12FT. RCA L/R TO RCA L/R STEREO

SS-01MSS

4" INTERNAL SATA III CABLE STRAI

FCBN410QD3C05

CABLE OPT 4X10 GBPS FULL-DUPLEX

FCBR425QB2C30

CABLE OPT 4X25G OMNI QSFP 30M

About Pluggable Cables

Pluggable Cable Assemblies includes pluggable equipment interconnects with interface and retention options.

When selecting an assembly, check connector family, protocol support, active or passive design and retention.

Confirm the exact port and equipment compatibility. Similar connector envelopes do not establish supported data rate or active-cable operation.

Pluggable Cables

Typical Applications

Potential uses vary by part number. Check the listed specifications and equipment requirements before selecting a product.

High-speed equipment links

High-speed equipment links

Match the connector family, protocol and supported equipment port.

Rack interconnect routing

Rack interconnect routing

Check cable length, retention and active or passive design against the port requirements.

Storage interface cabling

Storage interface cabling

Confirm the exact interface and equipment compatibility before replacement.

Port retention checks

Port retention checks

Check latch access and connector orientation as well as electrical compatibility.

Shielded pluggable cables vs. Unshielded pluggable cables

Compare the interfaces, construction and selection details of these two product options.

Shielded pluggable cables

Representative listed part: 1110251208.

  • Cable Connectors CXP
  • Connector Type Plug to Plug
  • Cable Type Round, Twin Axial
  • Shielding Shielded
  • Features Pull Tab
  • Frequency - Max 120Gbps

Unshielded pluggable cables

Representative listed part: 2015911010.

  • Cable Connectors QSFP
  • Connector Type Plug to Plug
  • Cable Type Round, Twin Axial
  • Shielding Unshielded
  • Features Pull Tab
  • Frequency - Max 56Gbps

The comparison describes common construction differences; final suitability depends on your electrical, mechanical and lifetime requirements.

Frequently Asked Questions

Practical answers to help you prepare your drawing and specifications.

How do I match a pluggable cable to an equipment port?

Check Cable Connectors, Connector Type and Gender at both ends, together with the equipment-supported interface. Similar module housings do not establish compatible electrical or signalling requirements.

Use the Features attribute and the equipment compatibility information for the exact part. Confirm the supported link and length; do not assume an active and passive assembly are direct substitutes.

Review Fastening Type, pull-tab clearance and Cable Type before specifying the installation. Provide the port spacing and routing constraints if the connector body or release mechanism has limited access.

Confirm the exact port and equipment compatibility. Similar connector envelopes do not establish supported data rate or active-cable operation.

1110251208 is shown as shielded pluggable cables, with Shielding listed as Shielded. 2015911010 is shown as unshielded pluggable cables, with Shielding listed as Unshielded. These are two examples, not a statement that every part has either specification.

Provide the original manufacturer and complete part number, or a drawing. For this range, compare connector family, protocol support, active or passive design and retention. Identify any requirement not covered by the listing rather than selecting only by length or appearance.

Supply a mating-interface drawing and the required connector family, protocol support, active or passive design and retention. Add quantity, destination and any inspection requirements. Changes must be reviewed for the selected construction before compatibility, pricing or delivery can be confirmed.

Tell us what you need to build

Send a drawing, a BOM, a part number or just one sentence. Our engineers review every enquiry and reply within 24 hours.

  • Engineering review within 24 hours
  • NDA available before drawings are shared
  • Free samples in 5-7 days after drawing approval
Inquiry Drawer

Review & Submit Request

This site uses cookies

We use cookies to collect information about how you use this site. We use this information to make the website work as well as possible and improve our services.more details