icon ISO 9001 · ISO 13485 · IATF 16949 · ISO 14001 certified manufacturer

Products

Explore products in this family. Open a product for details, or send us your drawing for a custom build.

Part number Description
S524-02M

CABLE MINISAS 4X M-M 2M

10143222-001LF

BARKLIP CABLE ASSY

2820333-4

C/A, INTERNAL HD MSAS, 100 OHM,

FCF8-30-01-L-24.00-S-1

FCF8 CABLE ASSEMBLY

2202502-4

C/A, 4X MINISAS HD, 28AWG PASSIV

1002973501

CABLE ASSY ZQSFP+ M-M 5M

1412-P31-06-6.00

3M TWIN AXIAL CABLE ASSEMBLIES F

8KC3-0726-0150

3M TWIN AXIAL PCI EXPRESS X16 EX

10054999-N0200BULF

CONN GIG-ARRAY PLUG

1410-P30-00-6.00

3M TWIN AXIAL CABLE ASSEMBLIES F

N280-05M-BK

CABLE ASSY SFP+ M-M 5M

9QM6-517-23-2.25

100G QSFP28 DIRECT ATTACH COPPER

1412-P32-06-5.00

3M TWIN AXIAL CABLE ASSEMBLIES F

1003461201

CABLE ZQSFP-2ZQSFP M-M 2M

2021431000

NPIO 4X 42 CKT N/SB STR TO STR .

747521701

CABLE ASSY SFP+ M-M 7M

10116531-R0050BULF

30AWG DENSI-SHIELD ASS'Y

2202503-4

C/A, 4X MINISAS HD, 30AWG PASSIV

FCBG125SD1C20B

CABLE ASSY SFP+ M-M 20M

PSF2PZC3.5MWH

CBL ASSY SFP28 25GIG DIRECT ATTA

FCBG410QD3C05

CABLE OPT 4X10 GBPS FULL-DUPLEX,

10054999-R0300BULF

CONN GIG-ARRAY PLUG

PSF1PZC3.5MRD

CBL ASSY SFP+ 10GIG DIRECT ATTAC

FCBG125SD1C01B

CABLE ASSY SFP+ M-M 1M

About Pluggable Cables

Pluggable Cable Assemblies includes pluggable equipment interconnects with interface and retention options.

When selecting an assembly, check connector family, protocol support, active or passive design and retention.

Confirm the exact port and equipment compatibility. Similar connector envelopes do not establish supported data rate or active-cable operation.

Pluggable Cables

Typical Applications

Potential uses vary by part number. Check the listed specifications and equipment requirements before selecting a product.

High-speed equipment links

High-speed equipment links

Match the connector family, protocol and supported equipment port.

Rack interconnect routing

Rack interconnect routing

Check cable length, retention and active or passive design against the port requirements.

Storage interface cabling

Storage interface cabling

Confirm the exact interface and equipment compatibility before replacement.

Port retention checks

Port retention checks

Check latch access and connector orientation as well as electrical compatibility.

Shielded pluggable cables vs. Unshielded pluggable cables

Compare the interfaces, construction and selection details of these two product options.

Shielded pluggable cables

Representative listed part: 1110251208.

  • Cable Connectors CXP
  • Connector Type Plug to Plug
  • Cable Type Round, Twin Axial
  • Shielding Shielded
  • Features Pull Tab
  • Frequency - Max 120Gbps

Unshielded pluggable cables

Representative listed part: 2015911010.

  • Cable Connectors QSFP
  • Connector Type Plug to Plug
  • Cable Type Round, Twin Axial
  • Shielding Unshielded
  • Features Pull Tab
  • Frequency - Max 56Gbps

The comparison describes common construction differences; final suitability depends on your electrical, mechanical and lifetime requirements.

Frequently Asked Questions

Practical answers to help you prepare your drawing and specifications.

How do I match a pluggable cable to an equipment port?

Check Cable Connectors, Connector Type and Gender at both ends, together with the equipment-supported interface. Similar module housings do not establish compatible electrical or signalling requirements.

Use the Features attribute and the equipment compatibility information for the exact part. Confirm the supported link and length; do not assume an active and passive assembly are direct substitutes.

Review Fastening Type, pull-tab clearance and Cable Type before specifying the installation. Provide the port spacing and routing constraints if the connector body or release mechanism has limited access.

Confirm the exact port and equipment compatibility. Similar connector envelopes do not establish supported data rate or active-cable operation.

1110251208 is shown as shielded pluggable cables, with Shielding listed as Shielded. 2015911010 is shown as unshielded pluggable cables, with Shielding listed as Unshielded. These are two examples, not a statement that every part has either specification.

Provide the original manufacturer and complete part number, or a drawing. For this range, compare connector family, protocol support, active or passive design and retention. Identify any requirement not covered by the listing rather than selecting only by length or appearance.

Supply a mating-interface drawing and the required connector family, protocol support, active or passive design and retention. Add quantity, destination and any inspection requirements. Changes must be reviewed for the selected construction before compatibility, pricing or delivery can be confirmed.

Tell us what you need to build

Send a drawing, a BOM, a part number or just one sentence. Our engineers review every enquiry and reply within 24 hours.

  • Engineering review within 24 hours
  • NDA available before drawings are shared
  • Free samples in 5-7 days after drawing approval
Inquiry Drawer

Review & Submit Request

This site uses cookies

We use cookies to collect information about how you use this site. We use this information to make the website work as well as possible and improve our services.more details