icon ISO 9001 · ISO 13485 · IATF 16949 · ISO 14001 certified manufacturer

Products

Explore products in this family. Open a product for details, or send us your drawing for a custom build.

Part number Description
3273912

PTFIX 10/18X4 WH

1028367

PTFIX 2X4 BK

3273083

PTFIX 6/6X2 5-NS35 PK

3273610

PTFIX 10/6X4-NS35 OG

3273215

PTFIX 6/6X2 5-NS35A PK

3273039

PTFIX 12X2 5-NS35 PK

3212444

PTTB 1 5/S/2P BK

3002368

PT 2X10/9X4 BU

3273886

PTFIX 10/12X4 GN

1047486

PTFIX 4/6X1 5-G VT

3274161

PTFIX 18X2 5-NS15A PK

3273614

PTFIX 10/12X4-NS35 GY

3273917

PTFIX 10/18X4 PK

1028074

PTFIX 2X2 5 BK

3273596

PTFIX 10/6X4-NS35 RD

3273612

PTFIX 10/6X4-NS35-FE

1046617

PTFIX 4X1 5 VT

3273998

PTFIX 10/6X4-G BN

3214082

PTU 35/4X6/6X2 5-FE

1046612

PTFIX 4X1 5 YE

3273888

PTFIX 10/12X4 BN

2052-321

2-CONDUCTOR MINIATURE THROUGH TB

1803112

MSTBVK 2 5/18-GF-5 08

272-303

THT MALE HEADER; 1.0 X 1.0 MM SO

About Terminal Blocks - Specialized

The Terminal Blocks - Specialized range covers wire connections organised in compatible terminal-block systems.

Compare wire range, pitch, mounting, jumper system and electrical ratings for the required installation. Use the exact mating part and installation dimensions specified for the selected item.

Review Type, Mounting Type, Number of Positions, Number of Levels and Terminal - Width on the individual product page before choosing a part.

Terminal Blocks - Specialized

Typical Applications

Potential uses vary by part number. Check the listed specifications and equipment requirements before selecting a product.

Control cabinets

Control cabinets

Terminal Blocks - Specialized can be evaluated for control cabinets. Match wire range, pitch, mounting, jumper system and electrical ratings to the equipment interface.

Equipment wiring

Equipment wiring

For equipment wiring, verify Type, Mounting Type, Number of Positions, Number of Levels and Terminal - Width on the selected Terminal Blocks - Specialized. Use the exact mating part and installation dimensions specified for the selected item.

Interface assemblies

Interface assemblies

In interface assemblies, allow for the required mounting, routing or termination space. Check wire range, pitch, mounting, jumper system and electrical ratings before assembly.

Terminal Blocks - Specialized inspection

Terminal Blocks - Specialized inspection

For terminal blocks - specialized inspection, identify the original Terminal Blocks - Specialized part number and mating arrangement. Compare Type, Mounting Type, Number of Positions, Number of Levels and Terminal - Width before substitution.

2016061615 configuration vs. 2016060633 configuration

Compare the interfaces, construction and selection details of these two product options.

2016061615 configuration

Example: 2016061615

  • Type Universal Clamp
  • Mounting Type DIN Rail or Panel Mount
  • Number of Positions 1
  • Number of Levels 1
  • Terminal - Width 19.2mm
  • Termination Style Screw
  • Current - UL 150 A

2016060633 configuration

Example: 2016060633

  • Type Universal Clamp
  • Mounting Type DIN Rail or Panel Mount
  • Number of Positions 1
  • Number of Levels 1
  • Terminal - Width 29.5mm
  • Termination Style Screw
  • Voltage - UL 600 V

The comparison describes common construction differences; final suitability depends on your electrical, mechanical and lifetime requirements.

Frequently Asked Questions

Practical answers to help you prepare your drawing and specifications.

What does Terminal Blocks - Specialized include?

This category covers wire connections organised in compatible terminal-block systems. Use the exact mating part and installation dimensions specified for the selected item.

Examples in this category include 1, 2 and 3. Match the selected Terminal Blocks - Specialized to the required wire range, pitch, mounting, jumper system and electrical ratings.

For Terminal Blocks - Specialized, check Type, Mounting Type, Number of Positions, Number of Levels and Terminal - Width against the equipment or mating-part drawing. Confirm the installed clearance and termination access as well as the nominal interface size.

Check wire range, pitch, mounting, jumper system and electrical ratings for the selected part. Use its stated operating conditions and complete assembly requirements; appearance alone does not establish the electrical or environmental rating.

Use the exact mating part and installation dimensions specified for the selected item. For Terminal Blocks - Specialized, identify the matching system and required assembly parts before ordering.

2016061615 specifies Type: Universal Clamp and Mounting Type: DIN Rail or Panel Mount. 2016060633 specifies Type: Universal Clamp and Mounting Type: DIN Rail or Panel Mount. Check the full mating and installation requirements before treating different Terminal Blocks - Specialized as replacements.

Send the manufacturer and full part number, quantity and required delivery destination. For this category, include wire range, pitch, mounting, jumper system and electrical ratings and a mating or installation drawing when a replacement is needed.

Tell us what you need to build

Send a drawing, a BOM, a part number or just one sentence. Our engineers review every enquiry and reply within 24 hours.

  • Engineering review within 24 hours
  • NDA available before drawings are shared
  • Free samples in 5-7 days after drawing approval
Inquiry Drawer

Review & Submit Request

This site uses cookies

We use cookies to collect information about how you use this site. We use this information to make the website work as well as possible and improve our services.more details