icon ISO 9001 · ISO 13485 · IATF 16949 · ISO 14001 certified manufacturer

Products

Explore products in this family. Open a product for details, or send us your drawing for a custom build.

Part number Description
2-35244-1

CONN SPLICE 14-16 AWG CRIMP

E43281N001

CONN SPLICE CRIMP

1601559-1

CONN SPLICE 19-22 AWG CRIMP

B-202-82

CONN SPLICE COAXIAL CABLE CRIMP

D-406-5002

CONN SPLICE 14-16 AWG CRIMP

1601766-1

CONN SPLICE 9-11.5 AWG CRIMP

D-436-82CS788

CONN SPLICE 20-26 AWG CRIMP

1217440-8

CONN SPLICE CRIMP

1601575-1

CONN SPLICE 19-22 AWG CRIMP

7-1195452-8

CONN SPLICE 410-1230 CMA CRIMP

CA6206-000

CONN WIRE CAP 7000-16000 CMA

650134N004

CONN SPLICE 16-22 AWG CRIMP

1601699-1

CONN SPLICE CRIMP

140723-1

CONN SPLICE 16-22 AWG CRIMP

D-436-36CS391

CONN BUTT SPLICE CRIMP

170152-3

CONN SPLICE 15-22 AWG CRIMP

1601825-1

CONN SPLICE 14-18 AWG CRIMP

1-141175-1

AMPLIVAR SPL 5 SERR

1116377-3

CONN INLINE TAP 12-14 AWG CRIMP

1601726-1

CONN SPLICE 12-15.5 AWG CRIMP

1-34070-1

CONN SPLICE 16-22 AWG CRIMP

171425-1

CONN INLINE TAP 18-20 AWG IDC

D-436-0126CS391

CONN SPLICE 1900-6755 CMA CRIMP

1601335-1

CONN SPLICE CRIMP

About Wire Splice Connectors

The Wire Splice Connectors range covers connections joining compatible wire conductors.

Compare wire range, conductor count, splice method and insulation for the required installation. Use the exact mating part and installation dimensions specified for the selected item.

Review Terminal Type, Number of Wire Entries, Termination, Wire Gauge and Insulation on the individual product page before choosing a part.

Wire Splice Connectors

Typical Applications

Potential uses vary by part number. Check the listed specifications and equipment requirements before selecting a product.

Harness junctions

Harness junctions

Wire Splice Connectors can be evaluated for harness junctions. Match wire range, conductor count, splice method and insulation to the equipment interface.

Equipment wiring

Equipment wiring

For equipment wiring, verify Terminal Type, Number of Wire Entries, Termination, Wire Gauge and Insulation on the selected Wire Splice Connectors. Use the exact mating part and installation dimensions specified for the selected item.

Splice verification

Splice verification

In splice verification, allow for the required mounting, routing or termination space. Check wire range, conductor count, splice method and insulation before assembly.

Wire Splice Connectors inspection

Wire Splice Connectors inspection

For wire splice connectors inspection, identify the original Wire Splice Connectors part number and mating arrangement. Compare Terminal Type, Number of Wire Entries, Termination, Wire Gauge and Insulation before substitution.

11545 configuration vs. 191540030 configuration

Compare the interfaces, construction and selection details of these two product options.

11545 configuration

Example: 11545

  • Terminal Type Butt Splice, Inline, Individual Openings
  • Number of Wire Entries 2
  • Termination Solder
  • Wire Gauge 10-12 AWG
  • Insulation Fully Insulated Heat Shrink
  • Color Yellow

191540030 configuration

Example: 191540030

  • Terminal Type Butt Splice, Inline, Individual Openings
  • Number of Wire Entries 2
  • Termination Crimp
  • Wire Gauge 10-12 AWG
  • Insulation Fully Insulated
  • Color Yellow

The comparison describes common construction differences; final suitability depends on your electrical, mechanical and lifetime requirements.

Frequently Asked Questions

Practical answers to help you prepare your drawing and specifications.

What does Wire Splice Connectors include?

This category covers connections joining compatible wire conductors. Use the exact mating part and installation dimensions specified for the selected item.

Examples in this category include Butt Splice, Inline, Individual Openings, Inline, Individual Openings (Parallel) and Butt Splice, Closed End, Individual Openings. Match the selected Wire Splice Connectors to the required wire range, conductor count, splice method and insulation.

For Wire Splice Connectors, check Terminal Type, Number of Wire Entries, Termination, Wire Gauge and Insulation against the equipment or mating-part drawing. Confirm the installed clearance and termination access as well as the nominal interface size.

Check wire range, conductor count, splice method and insulation for the selected part. Use its stated operating conditions and complete assembly requirements; appearance alone does not establish the electrical or environmental rating.

Use the exact mating part and installation dimensions specified for the selected item. For Wire Splice Connectors, identify the matching system and required assembly parts before ordering.

11545 specifies Terminal Type: Butt Splice, Inline, Individual Openings and Number of Wire Entries: 2. 191540030 specifies Terminal Type: Butt Splice, Inline, Individual Openings and Number of Wire Entries: 2. Check the full mating and installation requirements before treating different Wire Splice Connectors as replacements.

Send the manufacturer and full part number, quantity and required delivery destination. For this category, include wire range, conductor count, splice method and insulation and a mating or installation drawing when a replacement is needed.

Tell us what you need to build

Send a drawing, a BOM, a part number or just one sentence. Our engineers review every enquiry and reply within 24 hours.

  • Engineering review within 24 hours
  • NDA available before drawings are shared
  • Free samples in 5-7 days after drawing approval
Inquiry Drawer

Review & Submit Request

This site uses cookies

We use cookies to collect information about how you use this site. We use this information to make the website work as well as possible and improve our services.more details