icon ISO 9001 · ISO 13485 · IATF 16949 · ISO 14001 certified manufacturer

Products

Explore products in this family. Open a product for details, or send us your drawing for a custom build.

Part number Description
A7OOB-0910M

CABLE D-SUB-AFN09B/AE09M/AFN09B

CS-DSDHD44MF0-010

CABLE ASSY HD44 SHLD GRAY 3.05M

CS-DSDHD62MM0-005

CABLE ASSY HD62 SHLD GRAY 1.52M

CS-DSDMDB15MF-025

CABLE ASSY DB15 SHLD GRAY 7.62M

834219050

CABLE ASY D TO MICR D 9P 914.4MM

CS-DSDHD78MF0-005

CABLE ASSY HD78 SHLD GRAY 1.52M

834219037

CABLE ASSY DB09 TO MICRO D 925MM

A7PPB-1510M

CABLE D-SUB-AMM15B/AE15M/AMM15B

M7WWK-0910R

D-SUB CABLE MFU09K/MC10M/MFU09K

A7PXB-3710G

CABLE D-SUB - AMM37B/AE37G/X

C7MMS-3706G

DSUB CABLE - CMP37S/AE37G/CMP37S

C7SXG-3706M

DSUB CABLE - CFM37G/AE37M/X

A7WWB-0906G

CABLE D-SUB-AFU09B/AE09G/AFU09B

A7NNB-0906G

CABLE D-SUB-AMN09B/AE09G/AMN09B

A7FXB-2510M

CABLE D-SUB - AFP25B/AE25M/X

M7OOK-0906R

D-SUB CABLE MFL09K/MC10M/MFL09K

M7WWK-0906R

D-SUB CABLE MFU09K/MC10M/MFU09K

A7OXB-1506M

CABLE D-SUB - AFN15B/AE15M/X

M7PSK-0910R

D-SUB CABLE MMM09K/MC10M/MFM09K

A7MXB-3706G

CABLE D-SUB - AMP37B/AE37G/X

M7VXK-3706J

D-SUB CABLE - MMU37K/MC37G/X

834229017

COMM-D RCPT 15 SKT 2-56 THD

M7WXK-3706J

D-SUB CABLE - MFU37K/MC37G/X

A7MFB-1506G

CABLE D-SUB-AMP15B/AE15G/AFP15B

About D-Sub Cables

D-Sub Cable Assemblies includes D-sub interconnects with different contact counts and end configurations.

When selecting an assembly, check contact count, gender, pinout, mounting hardware and cable shielding.

Straight-through, crossover and equipment-specific D-sub cables may use similar shells. Confirm the pin-to-pin map instead of inferring it from the connector size.

D-Sub Cables

Typical Applications

Potential uses vary by part number. Check the listed specifications and equipment requirements before selecting a product.

Serial controller links

Serial controller links

Confirm the serial standard and pinout; a D-sub shell does not identify the electrical interface.

Instrument rear-panel wiring

Instrument rear-panel wiring

Check contact count, gender and screw-lock hardware against the instrument drawing.

Legacy workstation servicing

Legacy workstation servicing

Distinguish straight-through, crossover and equipment-specific wiring before replacement.

Panel extension routing

Panel extension routing

Match both ends and allow clearance for the backshell, mounting screws and cable bend.

Male D-sub termination vs. Female D-sub termination

Compare the interfaces, construction and selection details of these two product options.

Male D-sub termination

Representative listed part: 1200980207.

  • 1st Connector Plug, Male Pins
  • 2nd Connector Plug, Male Pins (2), Right Angle
  • Type DB9
  • Number of Positions 9
  • Shielding Shielded
  • Length 3.28' (1.00m)

Female D-sub termination

Representative listed part: M7OOK-0906J.

  • 1st Connector Receptacle, Female Sockets
  • 2nd Connector Receptacle, Female Sockets
  • Type DB9
  • Number of Positions 9
  • Shielding Unshielded
  • Length 6.00' (1.83m)

The comparison describes common construction differences; final suitability depends on your electrical, mechanical and lifetime requirements.

Frequently Asked Questions

Practical answers to help you prepare your drawing and specifications.

Are D-sub cables with the same pin count wired identically?

Check both mating ends and obtain the pin-to-pin wiring required by the equipment. Position count identifies only part of the connection; it does not document straight-through wiring, crossovers or unused contacts.

Read the contact description at both ends and compare it with the equipment connector. Specify the shell size, position count and retention arrangement as well as male pins or female sockets.

Confirm the lead identification, length and termination requirements for the installation. A connector-to-leads assembly requires a defined wiring plan rather than the same mating arrangement as a fully terminated cable.

Straight-through, crossover and equipment-specific D-sub cables may use similar shells. Confirm the pin-to-pin map instead of inferring it from the connector size.

1200980207 is shown as male d-sub termination, with 1st Connector listed as Plug, Male Pins. M7OOK-0906J is shown as female d-sub termination, with 1st Connector listed as Receptacle, Female Sockets. These are two examples, not a statement that every part has either specification.

Provide the original manufacturer and complete part number, or a drawing. For this range, compare contact count, gender, pinout, mounting hardware and cable shielding. Identify any requirement not covered by the listing rather than selecting only by length or appearance.

Supply a mating-interface drawing and the required contact count, gender, pinout, mounting hardware and cable shielding. Add quantity, destination and any inspection requirements. Changes must be reviewed for the selected construction before compatibility, pricing or delivery can be confirmed.

Tell us what you need to build

Send a drawing, a BOM, a part number or just one sentence. Our engineers review every enquiry and reply within 24 hours.

  • Engineering review within 24 hours
  • NDA available before drawings are shared
  • Free samples in 5-7 days after drawing approval
Inquiry Drawer

Review & Submit Request

This site uses cookies

We use cookies to collect information about how you use this site. We use this information to make the website work as well as possible and improve our services.more details