icon ISO 9001 · ISO 13485 · IATF 16949 · ISO 14001 certified manufacturer

Products

Explore products in this family. Open a product for details, or send us your drawing for a custom build.

Part number Description
745551103

X8 IPASS CBL ASSY 2.515M HP AH33

747529666

R7,CBL,ENET,SFP+ TO SFP+,CU,10G,

2015912002

DDQ TO DDQ 25G 1M 32AWG CBL ASSY

1003463222

ZQSFP+ TO 2ZQSFP+ 26AWG 2.25M CB

2113011218

SLIMSAS 8X LP STR TO SLIMSAS 8X

2033662102

DDQ TO 2ZQ 25G 1M 32AWG CBL ASSY

747577050

QSFPQSFP CUPATCH CBL 0.5M 26AWG

2157321008

MCIO 8X RE TO SLIMSAS 8X STR

747576603

QSFPQSFP CU PATCH CBL 3M 26 AWG

1110751212

4X MINISAS HD TO SFP+ 4.0M 28AWG

1110771900

8X HD TO 8X HD PCIE GEN 3 CBL AS

745095008

12X - 12X CUSTOM PINOUT,16 PR,UN

2033662106

DDQ TO 2ZQ 25G 3M 30AWG CBL ASSY

2150711040

MCIO 8X STR TO MCIO 8X STR, 85OH

1064152208

IPASS+ HD, MINI SAS, AOC, 8M

745552000

X8 IPASS CBL ASSY,CUSTOM PINOUT,

747529093

CUSTOM VRSN OF CISCO NUOVA 74752

1001890433

4XHD SHORTBODY,250MM S/B 220MM 0

2113011204

SLIMSASLP8X STRTO2*4X STR100OHM6

FCBR410QB1C15

CABLE OPT 4X10 GBPS FULL-DUPLEX,

747642302

QSFP+TO 4 SFP+1M 30AWG CU BREAKO

1110753109

IPASS X4 HD 3.0 6.0M 24AWG FRU 0

2079901028

SLIMSAS 8X STR TO 2* HD STR

2116146145

8X SLIMSAS STR A/S TO 8X HD STR

About Pluggable Cables

Pluggable Cable Assemblies includes pluggable equipment interconnects with interface and retention options.

When selecting an assembly, check connector family, protocol support, active or passive design and retention.

Confirm the exact port and equipment compatibility. Similar connector envelopes do not establish supported data rate or active-cable operation.

Pluggable Cables

Typical Applications

Potential uses vary by part number. Check the listed specifications and equipment requirements before selecting a product.

High-speed equipment links

High-speed equipment links

Match the connector family, protocol and supported equipment port.

Rack interconnect routing

Rack interconnect routing

Check cable length, retention and active or passive design against the port requirements.

Storage interface cabling

Storage interface cabling

Confirm the exact interface and equipment compatibility before replacement.

Port retention checks

Port retention checks

Check latch access and connector orientation as well as electrical compatibility.

Shielded pluggable cables vs. Unshielded pluggable cables

Compare the interfaces, construction and selection details of these two product options.

Shielded pluggable cables

Representative listed part: 1110251208.

  • Cable Connectors CXP
  • Connector Type Plug to Plug
  • Cable Type Round, Twin Axial
  • Shielding Shielded
  • Features Pull Tab
  • Frequency - Max 120Gbps

Unshielded pluggable cables

Representative listed part: 2015911010.

  • Cable Connectors QSFP
  • Connector Type Plug to Plug
  • Cable Type Round, Twin Axial
  • Shielding Unshielded
  • Features Pull Tab
  • Frequency - Max 56Gbps

The comparison describes common construction differences; final suitability depends on your electrical, mechanical and lifetime requirements.

Frequently Asked Questions

Practical answers to help you prepare your drawing and specifications.

How do I match a pluggable cable to an equipment port?

Check Cable Connectors, Connector Type and Gender at both ends, together with the equipment-supported interface. Similar module housings do not establish compatible electrical or signalling requirements.

Use the Features attribute and the equipment compatibility information for the exact part. Confirm the supported link and length; do not assume an active and passive assembly are direct substitutes.

Review Fastening Type, pull-tab clearance and Cable Type before specifying the installation. Provide the port spacing and routing constraints if the connector body or release mechanism has limited access.

Confirm the exact port and equipment compatibility. Similar connector envelopes do not establish supported data rate or active-cable operation.

1110251208 is shown as shielded pluggable cables, with Shielding listed as Shielded. 2015911010 is shown as unshielded pluggable cables, with Shielding listed as Unshielded. These are two examples, not a statement that every part has either specification.

Provide the original manufacturer and complete part number, or a drawing. For this range, compare connector family, protocol support, active or passive design and retention. Identify any requirement not covered by the listing rather than selecting only by length or appearance.

Supply a mating-interface drawing and the required connector family, protocol support, active or passive design and retention. Add quantity, destination and any inspection requirements. Changes must be reviewed for the selected construction before compatibility, pricing or delivery can be confirmed.

Tell us what you need to build

Send a drawing, a BOM, a part number or just one sentence. Our engineers review every enquiry and reply within 24 hours.

  • Engineering review within 24 hours
  • NDA available before drawings are shared
  • Free samples in 5-7 days after drawing approval
Inquiry Drawer

Review & Submit Request

This site uses cookies

We use cookies to collect information about how you use this site. We use this information to make the website work as well as possible and improve our services.more details